Inquiry list · 0 selectedReview & send inquiry →

WINYI WY0735 Gloria: compare the opening and output, not the percentage labels

WINYI WY0735 air-pulse stimulator shown in the manufacturer's catalog photograph
Manufacturer catalog image. QQIP has not physically tested the device; product claims below retain their source and limits.
WINYI · Manufacturer profile

WY0735 Gloria is a compact air-pulse stimulator with five selectable intensity states. Its catalog percentages describe those selections, but do not establish a physical pressure value. For a buyer comparing small air-pulse devices, the missing opening geometry and output measurement are more useful questions than whether another listing uses a larger percentage.

Ask about WY0735
Mechanism
Five air-pulse levels [1]
Size & mass
Approx. 95 × 58 × 47 mm · 90 g [1]
Power
170 mAh lithium cell · magnetic cable [1]
Order routes
Standard or color/logo variant [1]

This page covers WY0735. It does not inherit app control, immersion resistance or other WINYI models' features.

Read the parameters as a sample specification, not an acceptance result.

The published figures below identify a starting configuration. The right-hand column explains what is still needed to turn that configuration into an order you can approve. Keep the dated manufacturer sheet alongside your accepted sample.

WY0735 supplier-published values · checked 9 October 2026 · no independent QQIP measurements
ParameterPublished specificationWhat to confirm
GeometryApprox. 95 × 58 × 47 mm; approx. 90 g net weight [1]The manufacturer identifies the mass as net weight. Request axis definitions, dimensional tolerances and a working-opening drawing; ask which removable parts are included in that net-weight configuration.
Contact materialSilicone [1]Identify the contact component, formulation and applicable records. A material name alone does not establish suitability for every use condition.
IntensityFive levels; catalog labels 40–80% [1]The reference basis and pressure waveform are not supplied. These labels cannot be converted into kPa or compared directly with another model's percentages.
Cell & input601230 lithium cell / 170 mAh; 5 V / 170 mA charge [1]Match the installed cell, protective design and cable. Input current and stored capacity are different quantities.
Charge & runtimeCharge ≤120 min; use ≥60 min [1]Agree level, load, starting charge and stop condition. Neither value is a measured result from your production batch.
Water resistanceIPX5 claimed [1]Request the exact finished-assembly report and care instructions. Do not substitute another model's rating or an immersion claim.
Sound≤60 dB at 30 cm claimed [1]The remaining setup, weighting, operating level and background conditions are not supplied. Agree a repeatable method before setting an acceptance limit.
Motor reference130 motor; 4,500 rpm ±10% no-load [1]No-load motor speed is not the device's delivered pressure cycle or a loaded output guarantee.

What would make the five levels comparable?

The supplier labels the selections 40%, 50%, 60%, 70% and 80%, without defining the reference quantity. Keep those as control labels until the supplier provides a physical output definition. [1]

What would make the five levels comparable?
Catalog referenceWhat it does not establishAsk for this instead
Five percentage statesAbsolute pressure, waveform or an equivalent setting on another productDefinition of the percentage reference and output measured with a stated fixture
No-load motor speedPressure cycling frequency at the contact opening under loadRelationship between motor, mechanism and measured finished-device output
Small exterior dimensionsOpening size, contact depth or behavior of the interfaceOpening drawing and a reference sample in the supplied configuration

Resolve the working opening before choosing a branded variant.

The outside dimensions answer a different question

The published envelope helps establish a compact format; it cannot show whether the opening meets a particular design brief. Request its diameter or other relevant dimensions, rim geometry and depth with an axis-labelled drawing. Record the head revision on the sample so a later color or enclosure change does not conceal an interface change.

Compare the same interface and conditions

Ask the supplier to propose a defined sample fixture and output method suitable for the actual mechanism. If a competing catalog reports pressure, compare only when the reference, fixture and operating conditions match. Do not convert the printed percentages into kPa or infer a user experience from them.

Check the particular cable and five-state sequence.

The current model page gives a 1.5-second long press for startup and shutdown. Startup selects the first level; a short press cycles the five levels with one indicator flash per change. These are the manufacturer’s instructions, not a QQIP physical test. [1]

  1. Confirm the contact drawing

    Ask for contact position, polarity, lead identity and approved input. Keep that cable with the approved sample. Another magnetic lead can look compatible without establishing the same electrical arrangement.

  2. Compare the sample with the stated startup sequence

    Check the 1.5-second long press, first-level startup and five short-press transitions against the dated instruction supplied with your sample. Record any difference before approving the control artwork. The published sequence does not establish that the device remembers the previous level after restart. [1]

  3. Separate the warning from sustained output

    WINYI says the indicator flashes rapidly when voltage stays below 3.3 V, followed by automatic shutdown. Its charging light pulses white and stays on when charging finishes. Ask how the at-least-60-minute claim was measured: level, contact load and whether the endpoint is warning, reduced output or shutdown. Those conditions are not stated in the catalog. [1]

An existing model is not a commitment to a new opening.

Color or marking on the existing configuration

The supplier advertises private-label projects and publishes general unchanged/customized minimums. Request a WY0735 quotation by color and complete set. Do not assume that a request for a different opening, pressure profile or control logic is included in a color/logo order. [1]

Water exposure is a separate evidence decision

The model page states that this device should not be immersed. Keep that limit with the actual care instructions and request matching assembly evidence if a water-resistance claim will appear in your package. A different WINYI model’s rating cannot extend this one’s instructions. [1]

Two questions to settle before comparing quotations.

Is a model labelled 100% necessarily stronger than this model’s 80% setting?

No common reference is established. Ask for comparable finished-device output measurements and test conditions, not a comparison of percentage labels.

Can a new working opening be treated as logo customization?

Not without a specific agreement. The interface may affect the mechanism and enclosure; request a separate development scope and revised evidence rather than assuming cosmetic-order terms cover it.

Sources and editorial review

QQIP Editorial reviewed the official WY0735 page on 9 October 2026 and wrote this guide for model comparison. Values, operating instructions and general order conditions are supplier statements. The purchasing interpretation is editorial analysis. QQIP has not physically tested this device, authenticated a model report, confirmed inventory or obtained a binding quotation.

  1. WINYI — WY0735 official model page ↗

    Model geometry, functions, power, control/indicator descriptions and supplier general order FAQ; reports, stock and order commitments not independently established.

How QQIP reviews published sources